PVC pressure ratings: temperature, derating and system limits

Check service limits

A pipe’s printed pressure rating applies at a stated temperature. Heat, joints, valves and pressure surges can reduce the usable limit of the finished system.

What does the PSI number on PVC pipe mean?

Figure 01 · Schematic
The printed pressure number belongs to a specific product and reference condition.Illustration, not to scale.

PSI means pounds per square inch. A pipe rating belongs to a specific product, size and reference temperature, commonly 73°F. It is not a blanket approval for all fluids, temperatures or assemblies.

Read the manufacturer’s table for the exact nominal size and schedule, then check the rest of the system.

Link to this answer

What is temperature derating?

Figure 02 · Schematic
Increasing temperature reduces the allowable pressure of PVC.Illustration, not to scale.

Derating reduces an allowable rating to account for changed conditions. For PVC, allowable pressure decreases as service temperature rises. Use the manufacturer’s correction factor at the design temperature.

Selected Charlotte PVC temperature factors
Temperature Multiply the 73°F pipe rating by
73°F 1.00
100°F 0.62
120°F 0.40
140°F 0.22

These are selected reference points, not a substitute for the current full table. Charlotte’s PVC maximum service temperature is 140°F.

Link to this answer

How do I use a temperature factor?

Figure 03 · Schematic
Illustrative pipe-only calculation at 120°F; check the remaining system limits.Illustration, not to scale.

Multiply the pipe rating at 73°F by the applicable factor. For a hypothetical pipe rated 400 psi at 73°F, the pipe-only calculation at 120°F is 400 × 0.40 = 160 psi.

That example does not approve a 160 psi system. Check fittings, joints, valves, fluid compatibility, surge and the manufacturer’s design requirements separately.

Link to this answer

Why can the system rating be lower than the pipe rating?

Figure 04 · Schematic
A lower-rated valve, fitting or connection can limit the complete assembly.Illustration, not to scale.

A valve, flange, union, threaded connection or other component can have a lower allowable pressure. The assembly must stay within every applicable limit at its actual temperature. Also account for pressure transients rather than relying only on the normal operating reading.

Link to this answer

Can I test PVC with compressed air?

Figure 05 · Schematic
Do not test these plastic pipe systems with compressed air or gas.Illustration, not to scale.

No. Charlotte prohibits compressed air or gas testing and compressed air or gas service in these plastic pipe systems because failure can be explosive. Follow the permitted liquid testing procedure and required joint cure time.

Link to this answer

Sources and technical references

Use the current product submittal and installation instructions for the exact pipe and fittings. These guides explain selection factors; the completed installation must meet its design and applicable code.