ReadyPipe Solutions · Knowledge Center

Pipe sizes explained: IPS, CTS, OD and ID

Measure & identify

Match pipe by its sizing system and measured outside diameter. The size on the label is a name, not necessarily a measurement.

Why does a ½-inch pipe measure more than ½ inch?

Figure 01 · Schematic
Nominal size names the pipe family. Measure OD to compare with the correct sizing table.Illustration, not to scale.

“Nominal” means the size used to identify a pipe family. It does not promise that the inside or outside measures that exact number. OD is the outside diameter, measured across the pipe. ID is the inside diameter, also called the bore.

Use the marking to identify the material and standard, then compare the OD with the correct table. Measuring the hole alone can lead you to the wrong fitting.

Link to this answer

What is the difference between IPS and CTS?

Figure 02 · Schematic
A ½-inch IPS pipe and a ½-inch CTS tube have different outside diameters.Illustration, not to scale.

IPS means Iron Pipe Size; plastic pipe can use this sizing system too. CTS means Copper Tube Size. The same nominal label gives different outside diameters in these two systems.

Reference outside diameters, inches
Nominal size IPS PVC CTS copper / CPVC
½ inch 0.840 0.625
¾ inch 1.050 0.875
2 inches 2.375 2.125

Matching OD is one check. The fitting must also be approved for the material, joining method and service.

Link to this answer

Why is the inside diameter different from the listed value?

Figure 03 · Schematic
The bore depends on both outside diameter and wall thickness.Illustration, not to scale.

Pipe is manufactured to dimensional tolerances. For ASTM D1785 PVC, both outside diameter and wall thickness have requirements. The wall is not uncontrolled. Because ordinary socket fittings fit around the outside, a reference ID should not be treated as a precision bore specification.

For a uniform round section, ID ≈ OD − twice the wall thickness. Actual wall thickness, roundness and measurement location affect the result. If an insert, sleeve or other part must fit inside, discuss the required clearance and actual measurements before ordering.

Link to this answer

Do Schedule 40 and Schedule 80 use different fittings?

Figure 04 · Schematic
The outside stays the same while a thicker wall reduces the bore.Illustration, not to scale.

At the same IPS nominal size, their outside diameters match. Schedule 80 has a thicker wall and therefore a smaller bore. Dimensional fit alone does not establish the pressure rating or approval of an assembled system.

Link to this answer

What should I measure before replacing a pipe under my sink?

Figure 05 · Schematic
A sink drain can use tubular parts, nuts and adapters. Identify the connection before matching pipe.Illustration, not to scale.

Photograph the markings and the connection. Record the OD, material, length and whether the joint uses a nut and washer, a solvent socket, threads or another adapter. Thin tubular sink-drain parts and Schedule 40 pipe are different product families; do not order a replacement from the “1½-inch” label alone.

Measure a clean, straight section with calipers if possible, and ask for a specification match if the existing pipe cannot be identified.

Link to this answer

How is plastic pipe formed during manufacturing?

Figure 06 · Schematic
An extrusion line forms, sizes and cools a continuous tube before it is cut.Illustration, not to scale.

In extrusion, heated plastic compound passes through a die that forms a continuous tube. Calibration and cooling equipment help control the shape before the pipe is pulled along and cut to length.

Manufacturing controls dimensions within specified limits; they do not make ordinary pipe a machined precision bore. For a tight internal fit, specify the actual clearance you need rather than relying on a nominal size.

Link to this answer

Sources and technical references

Use the current product submittal and installation instructions for the exact pipe and fittings. These guides explain selection factors; the completed installation must meet its design and applicable code.

Need help matching an existing piece? Send the marking, measurements and intended use.