How to measure and order a cut length of pipe
Order the end-to-end length of the pipe itself. Confirm inches versus feet, allow for fitting insertion, and leave room for the stated cutting tolerance.
Are the cut lengths in inches or feet?
Read the unit shown with the length option. 48 inches = 4 feet; it is not 48 feet. Diameter and length are separate measurements: a “2-inch pipe, 48-inch length” describes the nominal diameter and a four-foot-long piece.
Before adding to cart, check the material, nominal diameter, schedule or type, selected length and quantity.
Link to this answerShould I order the gap between my fittings?
The cut length is measured from one pipe end to the other. A pipe that enters sockets extends inside the fittings, so the visible gap is not usually the required cut length.
For a simple straight piece between two facing socket openings, the required length includes the visible gap plus the specified insertion at both ends. Verify the actual fitting geometry and assembly instructions; there is no universal socket allowance.
Link to this answerWhat is ReadyPipe’s cut-length tolerance?
The supplied length may be up to ¼ inch shorter or longer than the ordered length (±¼ inch). 96-inch orders are intentionally cut to 95¾ inches to keep the finished package within 96 inches. For other standard lengths, we aim to be much closer, with 99% of cuts within ±⅛ inch. Machinery and normal handling introduce variation.
A cut within the stated tolerance is not a cutting error. Standard listed lengths may still be returned within 14 days after delivery for a full product refund when returned in the same condition as sent. Custom-cut returns carry a 25% restocking fee unless we are at fault. Customers pay return shipping when we are not at fault. See our return and refund policy for full terms. If your assembly needs tighter control, contact us before ordering to discuss the requirement.
Link to this answerWhat does ±¼ inch mean on a 48-inch piece?
A piece ordered at 48 inches may measure from 47¾ to 48¼ inches and remain within the stated cut-length tolerance. This is a length tolerance; it does not describe the allowed variation in the pipe’s diameter or wall.
Do not design a no-adjustment assembly around an exact end-to-end measurement without accounting for this range.
Link to this answerWhat else should I measure for a replacement?
Record the pipe’s OD on a clean straight section, its marking, material, nominal size and schedule or tube type. Note the connection style and any required end preparation. A short offcut may not carry the full printed marking.
Link to this answerCan I order by inside diameter for an insert?
Published IDs are reference dimensions. Wall thickness and manufacturing variation affect the actual opening. If another part must fit inside the pipe, provide the required clearance and discuss actual measurements before purchasing. Cut-length accuracy and bore accuracy are separate requirements.
Link to this answerSources and technical references
Use the current product submittal and installation instructions for the exact pipe and fittings. These guides explain selection factors; the completed installation must meet its design and applicable code.
Need help matching an existing piece? Send the marking, measurements and intended use.