4" Schedule 40 PVC Pipe
4" Schedule 40 PVC Pipe - is backordered and will ship as soon as it is back in stock.
Cut-length tolerance — ±¼ in. (±0.25 in.)
Applies to every length option, per piece: the cut may be up to ¼ inch shorter or longer than the length ordered. Standard listed lengths may be returned within 14 days after delivery in the same condition as sent. See the return and refund policy.
96-inch orders are intentionally cut to 95¾ inches so the finished package stays within 96 inches. For other standard lengths, we strive for closer cuts, with 99% within ±⅛ inch. Equipment limitations and operator variation mean the full ±¼ in. tolerance still applies.
Need a tighter length tolerance? Contact us before ordering.
Check Transit Time
Estimates. Dispatch timing may affect arrival. Final shipping price at checkout.
Ordering for a project or business?Volume pricing · mixed cut lists · special requirements
Let’s price your project.
Whether you need 100 identical pieces or a full cut list, send us the details. We’ll confirm your price and delivery options before you order.
Couldn't load pickup availability
Key specifications
- Material
- PVC Type I, Grade I
- Pipe standard
- ASTM D1785
- Nominal size
- 4 in. IPS
- Wall designation
- Schedule 40
- Outside diameter
- 4.500 in.
- Minimum wall
- 0.237 in.
- Inside diameter (reference)*
- ≈ 4.026 in.
- Cut-length tolerance
- ±¼ in. (±0.25 in.)
- Pressure / service
- 220 psi water at 73°F
- Service temperature
- 140°F max; derate above 73°F
Inside diameter & manufacturing tolerances
*Calculated reference ID: 4.500 − (2 × 0.237) = 4.026 in. This uses the published average outside diameter and minimum wall. It is not a measured or guaranteed bore; actual ID can differ by more than 0.01 in.
ASTM D1785 specifies dimensional requirements, including outside diameter and wall thickness. Standard compatible socket fittings mate with the outside surface. Permitted variation in OD and wall thickness changes the ID; wall thickness is not unrestricted.
For this 4-inch Schedule 40 size, ASTM D1785-21, Tables 1–2 lists average OD 4.500 ±0.009 in. and wall 0.237–0.265 in. These 2021 dimensional references do not guarantee the ID.
Need an exact inside fit? Contact us before ordering. Do not rely on a reference ID for a close-fitting insert or telescoping assembly.
Technical documentation
4-inch nominal Schedule 40 PVC pipe, supplied in selectable cut lengths.
Technical specifications
| Nominal size | 4 in. IPS |
|---|---|
| Material | PVC Type I, Grade I |
| Wall designation | Schedule 40 |
| Average outside diameter | 4.500 in. |
| Minimum wall thickness | .237 in. |
| Maximum working pressure at 73 degrees F | 220 psi, water |
| Pipe standard | ASTM D1785 |
| Maximum service temperature | 140 degrees F; pressure derating required above 73 degrees F |
| Available cut lengths | 4, 6, 12, 18, 24, 36, 48, 60, 72, 84, 96 in. |
| Inside diameter (reference)* | ≈ 4.026 in. — see the manufacturing-tolerance note above. |
| Cut-length tolerance | ±¼ in. (±0.25 in.) per piece; see the cutting policy above. |
Typical applications
Water distribution, landscape irrigation headers, pump discharge and process-water piping where PVC, the pressure class and chemical compatibility meet the design specification.
Selection and installation
Size by IPS outside diameter, pressure at operating temperature, flow and system demand. Use pressure-rated PVC fittings and approved primer and solvent cement. Fittings and joints can limit the system rating. Do not use for compressed air or gas.
Technical reference
Manufacturer data sheet. Dimensions and ratings are manufacturer reference values for the stated pipe class; confirm markings on the supplied piece and the project specification.